Air treatment unit made of 2 components. the components are filter/regulator with gauge, lubricator and an JGT model fixing bracket.
Order codes
J 2 P . 3 8 . M10 . 0 0 . 0 0
1 2 3 4 5
1 Series
J2 Air treatment unit made of 2 components
2 Version
T Polycarbonate bowl for M5 and G1/4 port size
P Polycarbonate bowl with metallic protection for G1/4-G3/8-G1/2-G3/4-G1 port size
3 Port size
... M5=M5 14=G1/4 38=G3/8 12=G1/2 34=G/4 1=G1
4 Gauge
M10 Gauge (standard) 0÷10 bar - if not request not indicate
5 Variants
A Automatic drain mode
F05 Filter degree: 5 µ;m
F50 Filter degree: 50 µ;m
M04 Gauge: scale 0÷4
R02 Max pressure adjustable: 2 bar
R04 Max pressure adjustable: 4 bar
NR Without relieving
DX Flow from right
For customized unit see the specific section.
Code example
Air treatment unit made of 2 components with knob down, polycarbonate bowl with metallic protection for G3/8 port size, with gauge, with automatic drain mode, without relieving.
J2P.38.M10.A.NR