Service: Air and compatible gases, any type particulate conductive or nonconductive.
Wetted Materials: 304 SS and PTFE.
Air Velocity Range: 300 ft/min and higher.
Minimum Detection: Standard: 10.0 pA, Optional: 5.0 pA and 0.5 pA.
Temperature Limits: Ambient: -15 to 160°F (-25 to 70°C); Process: Standard: -40 to 250°F (-40 to 120°C); Optional: -40 to 450°F (-40 to 232°C).
Pressure Limit: 10 psi (0.69 bar).
Power Requirement: 18-28 VDC (24V Nominal).
Output Signal: 4-20 mA.
Loop Resistance: 300 Ohms maximum.
Current Consumption: Powered from 4-20 mA loop.
Electrical Consumption: Terminal Block.
Process Connection: See Model Chart on Ordering Page.
Enclosure Rating: Weatherproof, NEMA 4X (IP 66).
Mounting Orientation: Any.
Weight: Varies with length of probe and type of mount.
Agency Approvals: CE Ordinary locations only, CSA